![]() ![]() 5 PS17 sensor check PRCB CN9-6 (ON) 12-J 6 SD1 operation check PRCB CN7-4 (REM) 13-D 7 M2 operation check PRCB CN11-10 to 13 13-B to C 8 Replace PS17. 4 Check the connector between SD1-relay CN25-PRCB CN7 for proper connection and correct as necessary. 3 Check the connector between PS17-PRCB CN9 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. Remedy: 1 Check the connector between M2-PRCB CN11 for proper connection and correct as necessary. ![]() The 1st transfer pressure sensor is not deactivated (pressed position) within a given period of time after the 1st transfer pressure solenoid has turned ON.The 1st transfer pressure sensor is not activated (retracted position) within a given period of time after the 1st transfer pressure solenoid has turned ON.Description: 1st transfer pressure / retraction failure. ![]()